Knowledge article
Tablet and Capsule Counter Changeover Checklist
A practical pre-run checklist for reviewing product properties, bottles, contact parts, cleaning, counter settings, line clearance, trial counts, and connected equipment.
Start with the product and container pair
Record the dosage form, dimensions, shape, coating, dust tendency, static behaviour, count per bottle, container dimensions, and bottle-neck opening. These inputs should be reviewed together because product separation, sensor presentation, discharge, and bottle transfer all depend on the actual combination.
Use confirmed project samples and specifications rather than assumptions. If the product or container changes, treat the new combination as a fresh setup review even when the nominal output target remains the same.
Confirm contact parts and feeding settings
Identify the product-contact and format parts included in the changeover. Clean, inspect, dry, and reassemble them according to the site's approved procedures and the supplied equipment documentation. Check that guides, channels, hoppers, nozzles, and other adjustable parts match the intended product and bottle.
Record qualified vibration, feeding, sensor, and count settings where available. Stored recipes can shorten setup, but the operator should still verify that the selected recipe belongs to the current product and container.
Complete line clearance before start-up
Remove previous product, bottles, closures, labels, rejected units, and superseded paperwork from the counter and connected line. Confirm the programmed count, product identification, container format, reject arrangement, sensor cleanliness, guards, and utilities before introducing the first production bottle.
Line clearance should include upstream and downstream equipment. An otherwise correct counter setup can still be disrupted by unstable bottle feeding, poor spacing, delayed capping, or accumulation after discharge.
Run a controlled start-up check
Use representative product and containers for the initial check. Observe separation, sensor detection, discharge into the bottle opening, container movement, and the response to no-bottle or interrupted-flow conditions. Verify the programmed count using the site's approved sampling method before increasing speed.
Document the actual trial result and any adjusted settings. If dust, overlapping units, chipped product, static, or container instability affects detection, pause and correct the cause instead of compensating with an unsupported speed or output claim.
Match the counter to the complete bottling line
Counter selection should consider the full route from bottle unscrambling through counting, insertion, capping, sealing, labelling, and collection. Required output, count per bottle, bottle opening, product behaviour, available space, utilities, and control interfaces determine whether a compact or higher-channel model is appropriate.
For a project review, compare confirmed samples and line requirements with the YOKO-16S-S, YOKO-10S, YOKO-24S, and YOKO-8S counter options. Final configuration should be documented in the quotation and technical agreement.
Turn the requirement into an equipment shortlist.
Share your material, format, capacity, utilities, and destination standard for a model-level review.
Request a technical discussionContinue the technical review
Related equipment
Standard Automatic Tablet Counter
The YOKO-16S-S standard automatic tablet counter is intended for tablet bottling and capsule bottling. Selection is reviewed against tablets and hard capsules, target output, utilities, and line interfaces. Final configuration is defined in the quotation and technical agreement.
- Reference range
- 1,200-9,600 bottles/hr
Capsule Counting and Bottling Machine
YOKO-10S is an automatic electronic counter for filling tablets, hard capsules, softgels, and selected solid units into bottles. The reference range is 1,200–3,000 bottles per hour at 30–100 units per bottle, with an adjustable count from 1 to 9,999 and bottle references of 30–100 mm diameter by 40–180 mm height. Stable output depends on product separation, count, bottle opening, dust, static, and connected-line behaviour.
- Reference range
- 1200-3000 (30-100 pcs/bottle) bottles/hr
Electronic Capsule Counter
The YOKO-24S electronic capsule counter is intended for tablet bottling and capsule bottling. Selection is reviewed against tablets and hard capsules, target output, utilities, and line interfaces. Final configuration is defined in the quotation and technical agreement.
- Reference range
- 600-4800 bottles/hr
Electronic Tablet Counter
The YOKO-8S electronic tablet counter is intended for tablet bottling and capsule bottling. Selection is reviewed against tablets and hard capsules, target output, utilities, and line interfaces. Final configuration is defined in the quotation and technical agreement.
- Reference range
- 600-2400 bottles/hr (80-100 pcs/bottle)
