Hot-air Sterilizing Oven for Glass Bottles, YOKO-RXG-D
YOKO-RXG-D product reference image. Final supplied configuration may vary.
Hot-air Sterilizing Oven for Glass Bottles, YOKO-RXG-D

YOKO-RXG-D product reference image. Final supplied configuration may vary.

Supplied by YOKO

YOKO-RXG-D

Hot-air Sterilizing Oven for Glass Bottles

The YOKO-RXG-D hot-air sterilizing oven for glass bottles is intended for glass ampoule sterilization and pre-filling container drying. Selection is reviewed against empty glass ampoules and compatible glass vials, target output, utilities, and line interfaces. Final configuration is defined in the quotation and technical agreement.

Reference capacity / range
Confirmed for the selected product and format
Dimensions
4500 × 1730 × 2400 mm
Power
51 kW
Typical applicationGlass ampoule sterilization · Pre-filling container drying
Material or formatEmpty glass ampoules · Compatible glass vials

Equipment purpose

What this machine is designed to do

Sterilizes and dries compatible glass ampoules or vials with controlled high-temperature air before filling.

Operating sequence

Working principle

Containers pass through a controlled hot-air chamber while temperature, airflow, and internal pressure are regulated for the selected process cycle.

Review points

  • Application review covers glass ampoule sterilization and pre-filling container drying.
  • Reference specifications include dimensions, power and weight for model comparison.
  • Material and format review includes empty glass ampoules and compatible glass vials.
  • Standalone or integrated supply scope is confirmed with utilities, guarding, interfaces, testing, and documentation.

Process fit

Applications and compatible materials

Use these references to frame the first technical discussion. Suitability is confirmed with actual material, format, and process data.

Typical applications

  • Glass ampoule sterilization
  • Pre-filling container drying

Material or format references

  • Empty glass ampoules
  • Compatible glass vials

Reference parameters

Technical specifications

Values are model references for initial selection. The quotation and approved technical agreement define the final supplied configuration.

Technical specifications

ModelYOKO-24000RXG-D
Maximum Sterilizing Temperature (°C)350
Applicable Container Specification1-2 ml ampoule
Power (kW)51
Dimensions (mm)4500 × 1730 × 2400
Weight (kg)3000

Before quotation

Configuration inputs

A useful quotation starts with the product, container or format, target output, available utilities, and destination requirements.

  • Product path, size range, and change parts for the confirmed application
  • Product-contact or chamber materials for empty glass ampoules and compatible glass vials
  • Destination electrical standard, control language, and utility interfaces
  • Upstream and downstream interfaces, guarding, testing, and documentation scope

Need a model-specific file set?

Start an inquiry for the current selection data, layout information, and privately supplied follow-up files.

Request documents

Controlled technical information

Public datasheet and private follow-up files

The public datasheet supports initial selection. Machine videos, operating manuals, and layout files are shared privately after an inquiry and technical discussion.

Technical datasheet

Download YOKO technical datasheet

This catalogue reference is not an operating manual. Final values are confirmed in the quotation and technical agreement.

Video and operating documentation

Machine videos and operating manuals are not published on public product pages. Ask your YOKO contact to supply relevant files privately after the project requirement has been reviewed.

Start a technical inquiry

Selection questions

Frequently asked questions

What information is needed to configure YOKO-RXG-D?

Provide the Compatible liquid formulations or other product characteristics, target sustained output, format or container details, utilities, destination standard, available space, and required documentation. YOKO uses these inputs to review the appropriate ampoule configuration.

How should the listed output for YOKO-RXG-D be interpreted?

The final output range depends on the selected configuration. It is not a guaranteed production commitment. Sustained performance must be confirmed with the actual material, product format, operating conditions, and agreed acceptance criteria.

Can YOKO-RXG-D be supplied for my destination standard?

Destination voltage, frequency, plug or wiring standard, control language, utilities, guarding, documentation, and any project-specific compliance requirements should be stated before quotation. The final supplied scope is defined in the approved technical agreement.

Model-level review

Request a configured quotation for YOKO-RXG-D

Share the material, product format, target sustained output, available utilities, destination standard, and expected documentation scope.

info@sxyoko.com

Current equipment context

Equipment
Hot-air Sterilizing Oven for Glass Bottles
Model
YOKO-RXG-D
Category
Ampoule

A short message is enough. Add product, capacity, or file details only if available.

By submitting, you agree to our Privacy Policy.